Introduction

To prospectively evaluate quantitative assessment of fluorescence optical imaging (FOI) for differentiation of synovitic from non-synovitic joints in patients suffering from rheumatoid arthritis (RA).

Methods

FOI of the hands was performed in patients with active RA, and a stratified quantitative fluorescence readout (FLRO) of 3 phases (1-120 s; 121-240 s; 241-360 s) was generated for 5 individual joints of the clinical predominant hand (carpal joint, metacarpophalangeal and proximal interphalangeal joints of digits II & III). To dissect the effect of the overall perfusion of the hand from the perfusion due to synovitis, a fluorescence ratio (FLRA) was additionally calculated, dividing each FLRO by the readout of the eponychium of digit II. The mean FLRO and FLRA were compared between joints with absent vs. present synovitis determined by clinical examination, grayscale, color Doppler ultrasonography, or magnetic resonance imaging (MRI).

Results

The analysis for 90 individual joints from 18 patients yielded FLRO ranging from 4.4 to 49.0 × 103, and FLRAs ranging from 0.37 to 2.27. Overall, the analyses based on the FLRA revealed a higher discrimination than the analyses related to the FLRO, demonstrating most significant differences in phases 2 and 3. A sensitivity of 26/39 (67%) and a specificity of 31/40 (77%) were calculated for FLRA of phase 3 using a cut-off value of more than 1.2 to detect MRI-confirmed synovitis with FOI.

Conclusions

FOI has a potential for visualizing synovitis in subjects with RA. For adequate FOI interpretation, quantitative analysis should be based on the novel FLRA calculated for phases 2 and 3.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​ar4304) contains supplementary material, which is available to authorized users.

Competing interests

JB is employed by the manufacturer of the system and software used to perform FOI in this study. All other authors declare no conflict of interest.

Authors’ contributions

VS, WH, MF, and BE designed the study. VS and WH carried out the acquisition and quantification of clinical examination, sonography, and FOI data. PH graded the MRI examinations. JB contributed to the utilization of the FOI quantification software. VS and BE performed the statistical analysis. VS, WH, PH, CS, MM, MF, and BE analyzed and interpreted the data and prepared the manuscript. All authors read and approved the final manuscript.
Abkürzungen
Anti-CCP antibodies
Anti-cyclic citrullinated peptide antibodies
CDUS
Color Doppler ultrasonography
CE
Clinical examination
CRP
C-reactive protein
DAS 28
Disease activity score of 28 joints
ESR
Erythrocyte sedimentation rate
FLRA
Fluorescence ratio
FLRO
Quantitative fluorescence readout
FOI
Fluorescence optical imaging
FOV
Field of view
GSUS
Grey-scale ultrasonography
ICG
Indocyanine green
MCP
Metacarpophalangeal
MRI
Magnetic resonance imaging
MTP
Metatarsophalangeal
PIP
Proximal interphalangeal
RA
Rheumatoid arthritis
RF
Rheumatoid factor
ROI
Regions of interest
SD
Standard deviation
SJ
Swollen joint
ST
Slice thickness
TE
Echo time
TJ
Tender joint
TR
Repetition time
US
Ultrasonography.

Introduction

Rheumatoid arthritis (RA) is an inflammatory disorder involving multiple joints [1, 2]. It is the most common chronic inflammatory joint disease with a prevalence of 0.5 to 1.0% [3, 4]. Persistent synovitis leads to massive joint destruction, and eventually causes irreversible disability in patients. It is of uttermost importance to recognize early synovitis, before substantial joint damage occurs and to start early and aggressive therapy in order to improve short- and long-term outcomes [57]. Therefore, sensitive and specific tools for early diagnosis of RA are necessary [5, 6]. The clinical examination (CE) is a prerequisite, but may miss subclinical inflammation in patients with early disease as well as in those who are in clinical remission under treatment [8]. Conventional x-ray examination is often used as an indicator of prognosis and represents the standard outcome measure of disease progression, but does not display the current disease activity [9]. Ultrasonography (US) is a valid tool in the assessment of patients with synovitis and in scoring the clinical activity [1012]. US is, however, a time-consuming, and operator-dependent technique and might miss signs of early arthritis [1315]. Magnetic resonance imaging (MRI) has proven to be the strongest independent predictor of radiographic progression in patients with RA [5, 9]. MRI, however, is costly, time-consuming, and not ubiquitously available. For fast and dynamic assessment of joint inflammation, US is more widely available than MRI in daily clinical practice [16]. The disadvantage of US is that it is a time-consuming method, and, apart from in clinical studies, the examination is usually limited to a reduced number of joints due to time constraints.
Fluorescence optical imaging (FOI) is a new, non-invasive and non-ionizing imaging technology with fast acquisition times [17, 18]. The major drawback of FOI is the limited tissue penetration of light; however, as inflammatory arthopathies typically affect the small joints of the hands and feet, this is not necessarily a significant limitation for this imaging method [19]. Under various experimental conditions, FOI proved to correspond to synovitis [17, 18, 2024]. In those experiments, early hyperemia of inflamed joints could be diagnosed by recording scattering and absorption patterns of light transmitted through inflamed finger joints. This approach has already been tested in humans [21, 25], which led to the development of an FOI system with fixed optical geometry (Xiralite X4; Mivenion GmbH, Berlin, Germany). The fluorescent dye indocyanine green (ICG) appears to be an appropriate tracer, because it has been shown to enhance inflamed joints [20, 26]. Furthermore, this substance has been approved by the Federal Drugs Administration. In a study by Scheel et al. [27] FOI provided information about the inflammation status of finger joints with a sensitivity and specificity of 80% and 89%, respectively. In a clinical study by Werner et al. [8] FOI had, taking MRI as a reference, a sensitivity of 76% and a specificity of 54%. Recently, another study by Meier et al. [19] reported that FOI had a sensitivity of 39.6% and a specificity of 85.2%, compared with MRI demonstrating conflicting results regarding the reliability of this new method. In 2011 Dziekan et al. [28] proposed a quantitative analysis of FOI using normalized variances of fluorescence time correlation functions. In their pivotal pilot study, the joints of healthy volunteers and patients with RA were compared, but no other imaging techniques besides FOI were employed. Therefore, the purpose of this study was to establish a novel quantitative readout for ICG-enhanced FOI to allow more accurate joint assessment and to prospectively compare this imaging method with CE, US, and contrast enhanced 1.5 T MRI for detection of inflamed and non-inflamed joints of the hands in patients with proven RA.

Methods

Patients

Patients with known RA seeking routine clinical care and reporting symptoms suggestive of wrist and/or finger joint involvement were asked to participate in the study. Inclusion criteria were an established diagnosis of RA according to the American College of Rheumatology criteria from 1987, elevated rheumatoid factor (RF), and/or elevated anti-cyclic citrullinated peptide (anti-CCP) antibodies, and reported symptoms suggestive of wrist and/or finger-joint involvement. Exclusion criteria were pregnancy, renal failure, increased skin pigmentation [29], known allergy against iodine, ICG or gadolinium, or other contraindications for MRI. The study was performed in compliance with the Declaration of Helsinki. The study protocol was approved by the ethics committee of the University Medical Center Regensburg. All study participants signed consent forms after receiving appropriate written and oral information prior to enrollment.
Demographical data (sex, age, disease duration) and laboratory data (RF, anti-CCP, serum C reactive protein (CRP) and erythrocyte sedimentation rate (ESR)) were derived by chart review. All patients received a standardized rheumatologic CE of the 28 joints included in the Disease Activity Score 28 (DAS28, [30]) by one of the authors (V.S. or W.H.) using a bimanual technique, documenting tender and swollen status for each joint. The DAS28 was calculated for each patient [30].
All data regarding clinical and imaging studies were obtained within two days after inclusion for each enrolled patient.

Ultrasonography

The joints included in the US7 score (wrist, metacarpophalangeal (MCP) and proximal interphalangeal (PIP) joints of the index (II) and middle (III) finger of the clinically dominant hand, and the metatarsophalangeal (MTP) joints of the second (II) and fifth (V) toe of the clinical predominant foot) were examined by ultrasonography by one of the authors (V.S. or W.H.) using a LOGIQ E9 (GE, Munich, Germany) ultrasound machine with a linear transducer (ML 6–15) with 15 MHz frequency [31]. Each joint was rated separately semiquantitatively (grades 0 to 3) for distension of the capsule due to synovitis with grey scale ultrasonography (GSUS) and for synovial vascularity with color Doppler ultrasonography (CDUS). The presence of synovitis was concluded for each mode if at least grade 1 findings were observed. For each patient the US7 score was calculated [31].

Magnetic resonance imaging

For each patient a gadolinium-enhanced MRI of the clinically dominant hand was performed using a 1.5 T high-field MR scanner. The main focus of the MRI examination was the evaluation of the carpal and MCP joints, and if included in the examination field also the evaluation of the PIP joints. The examination protocol was performed analog to routine clinical practice and in line with the recommendations of the RAMRIS (Rheumatoid Arthritis MRI Scoring system) [32]. Fat saturated proton or T2-weighted and contrast-enhanced T1-weighted sequences were used in at least one coronal and axial plane. Additional unenhanced T1-weighted sequences were acquired in coronal plane. One of the 18 patients was examined with fat saturated proton-weighted and T2-weighted sequences, and the other patients were analyzed utilizing only proton-weighted images. For all patients the contrast-enhanced T1-weighted images were fat saturated using spectral saturating technique. Gadoteric acid (Dotarem®, Guerbet, Villepinte, France) was applied as intravenous contrast agent using a dosage of 0.2 ml/kg. (The majority of patients were examined using the following MRI protocol: prone position with the hand placed over the head in an extremity surface flex coil, coronal fat saturated proton-weighted turbo spin echo (Cor PD TSE fs), echo time (TE) 29/repetition time (TR) 2260, slice thickness (ST) 2.5 mm, gap 0.25 mm, field of view (FOV) 240 × 320 mm2, scan time: 1 minute 40 seconds. Sagittal fat saturated proton-weighted turbo spin echo (Sag PD TSE fs), TE 29/TR 3630, ST 3 mm, gap 0.3 mm, FOV 240 × 320 mm2, scan time: 1 minute 45 seconds. Coronal T1-weighted turbo spin echo (Cor T1 TSE), TE 14/TR 586, ST 2.5 mm, gap 0.25 mm, FOV 256 × 320 mm2, scan time: 2 minutes 16 seconds. Axial contrast-enhanced T1-weighted fat saturated turbo spin echo (Axial CE T1 TSE fs), TE 14/TR 732, ST 2.5 mm, gap 0.25 mm, FOV 236 × 192 mm2, scan time: 1 minute 40 seconds.) All MRI scans were read according to the RAMRIS scoring system by an experienced radiologist (P.H., seven years of MRI experience) blinded to clinical and ultrasonography data. The presence of synovitis was concluded for each joint, if at least grade one findings were observed. Additionally, the extensor tendons overlying the joint were evaluated for the presence of tenosynovitis. The RAMRIS score has been calculated for each patient.

Fluorescence optical imaging

A commercially available, near-infrared fluorescence imaging system (Xiralite X4, Mivenion GmbH, Berlin, Germany) was used in this study. The working principle is based on the excitation of ICG dye by light emitting diodes and the detection of fluorescence signals with a sensitive camera. The instrument is controlled by a complementary PC and records image sequences with a standardized frame rate of one frame (image) per second over a period of six minutes. Thus, a stack of 360 images is provided for each individual examination.
The FOI examination followed a standardized procedure: both hands were placed on a preformed hand rest. Ten seconds after starting the examination, an ICG bolus (0.1 mg/kg) was injected manually in the cubital vein over the period of approximately one second (ICG-Pulsion, Pulsion, Feldkirchen, Germany). Any alteration of fluorophor concentration can be depicted as alteration of signal intensity. Due to hepatic clearance of ICG, FOI signals decay with a time constant of typically three to four minutes. In a pilot study, it was found that the relative FOI signal intensities within one frame do not change significantly after an imaging period of six minutes. Therefore, this duration was determined as the standard examination time.
FOI findings were analyzed using software provided by the manufacturer (Xiralyze (version 1.0.3), Mivenion GmbH, Berlin, Germany). Electronically generated composite images (CI) were calculated from the mean fluorescence signal intensities of an image stack of sequential subsets of acquired images. In line with two previous publications, we defined CI for three sequential phases with a duration of 120 seconds each (1 to 120 seconds, 121 to 240 seconds, and 241 to 360 seconds) [8, 19]. To allow for quantitative assessment, five joints (wrist, MCP II and III, and PIP II and III) of each patient were analyzed using circular regions of interest (ROI), with the size of each ROI defined according to the anatomical size of the corresponding joint (a diameter of 22 pixel for wrists, 12 pixel for MCP- and 10 pixel for PIP-joints; see Figure 1). The resulting fluorescence readout (FLRO) represents, therefore, the mean fluorescence intensity per pixel of the analyzed CI.
To evaluate the influence of the general perfusion of the whole hand on the readout of individual joints, an additional analysis method was developed: the FLRO at the eponychium of the index finger was determined in each patient, an anatomical site not known to be involved in inflammatory processes in patients with RA (using a circular ROI with a diameter of five pixel, placed centrally over the eponychium). In order to standardize individual joint FOI readout results for the general perfusion, we established a fluorescence ratio (FLRA) for each joint by dividing the readout of the joint ROI by the readout of the eponychium of the index finger.

Statistical analysis

Data evaluation and statistical analyses were performed using SPSS software (version 20, IBM, Ehningen, Germany). We compared the mean FLRO and mean FLRAs of joints with compared with those without evidence of synovitis derived by clinical evaluation (tender or swollen joints) or by established imaging techniques (GSUS, CDUS, MRI) for all three phases and the sum of the three phases using Student’s t-test statistic. Statistical significance was concluded when two-sided P values were below 0.05.

Results

The study population included 18 subjects, eight women (44%) and 10 men (56%), with a mean (± standard deviation (SD)) age of 63.0 (± 10.0) years. All subjects tolerated the procedure well, and no adverse events were observed. Patient’s clinical and laboratory characteristics, and US and MRI scores are displayed in Table 1. To illustrate the comparison of the employed imaging methods, Figure 2 displays the carpal arthritis of a 50-year-old subject with RA.
Table 1
Patient characteristics and results of laboratory and imaging studies *
All patients, n (%)
18 (100%)
Male, n (%)
10 (56%)
Female, n (%)
8 (44%)
Age
63.0 ± 10.0 years
Disease duration
4.9 ± 4.4 years
ESR
25.4 ± 25.3 mm/hour
CRP
17.2 ± 19.6 mg/l
CE, tender joints
7.3 ± 5.0
CE, swollen joints
5.4 ± 5.4
Disease activity (DAS28)
4.6 ± 1.6
Ultrasonography score (US7)
13.8 ± 9.4
MRI score (RAMRIS)
14.6 ± 10.0
* Except where indicated otherwise, values are the mean ± SD. CE clinical examination, CRP C-reactive protein, DAS28 disease activity score of 28 joints, ESR erythrocyte sedimentation rate, MRI magnetic resonance imaging.
A total of 90 joints from the 18 patients were analyzed (18 carpal, 36 MCP, and 36 PIP joints). All 90 joints were evaluated by CE and US and 79 by MRI. The CE revealed 26 of 90 (29%) swollen joints (SJ) and 44 of 90 (49%) tender joints (TJ). The GSUS revealed 39 of 90 (43%), CDUS revealed 23 of 90 (26%) and MRI revealed 39 of 79 (49%) joints that displayed findings consistent with active synovitis. Four of the 79 joints (5%) evaluated by MRI also displayed tenosynovitis of the overlying extensor tendons, but in all four instances the adjoining joint also showed signs of synovitis.
The quantitative analysis for individual joints of the FLRO yielded values ranging from 4.4 to 49.0 × 103 (mean 19.1 ± SD 9.5) for phase 1, 4.2 to 47.9 × 103 (mean 19.6 ± SD 9.2) for phase 2, and 2.6 to 40.9 × 103 (mean 12.8 ± SD 6.8) for phase 3. The results of the quantitative analysis of the FOI data are displayed in Table 2. The comparison yielded significant differences of the mean FLRO between joints with compared to those without evidence of active synovitis determined by US and MRI, but not by CE. Of note, there were significant differences of the mean FLRO between joints with compared to those without synovitis determined by GSUS and MRI for phases 2 and 3, whereas significant differences have been only observed by CDUS in phases 1 and 2.
Table 2
Mean fluorescence readout for joints with compared to those without evidence of synovitis determined by clinical examination or established imaging techniques #
  
FOI phase 1 (1 – 120 seconds)
FOI phase 2 (121 – 240 seconds)
FOI phase 3 (241 – 360 seconds)
Synovitis
n
mean ± SD
P
mean ± SD
P
mean ± SD
P
TJ yes
44
19.1 ± 11.0
ns
19.6 ± 9.0
ns
12.6 ± 5.7
ns
TJ no
46
19.2 ± 7.8
19.6 ± 9.4
13.0 ± 7.8
SJ yes
26
22.7 ± 12.6
ns
22.3 ± 9.8
ns
14.1 ± 6.2
ns
SJ no
64
17.7 ± 7.5
18.5 ± 8.7
12.3 ± 7.0
GSUS yes
39
21.0 ± 11.4
ns
23.5 ± 10.4
**
15.8 ± 7.9
**
GSUS no
51
17.7 ± 7.5
16.6 ± 6.8
10.5 ± 4.8
CDUS yes
23
24.1 ± 12.3
*
23.8 ± 9.3
*
15.0 ± 5.9
ns
CDUS no
67
17.5 ± 7.7
18.2 ± 8.7
12.0 ± 7.0
MRI yes
39§
20.9 ± 10.1
ns
22.3 ± 9.5
*
14.8 ± 7.3
*
MRI no
40§
17.8 ± 9.6
17.2 ± 9.2
10.9 ± 6.5
All
90
19.1 ± 9.4
 
19.6 ± 9.2
 
12.8 ± 6.8
 
# Fluorescence readout results are displayed for better readability divided by 103; § 11 joints could not be evaluated with MRI; *P<0.05; **P<0.01.
CDUS color Doppler ultrasonography, FOI fluorescence optical imaging, GSUS grey-scale ultrasonography, MRI magnetic resonance imaging; ns, comparison was not significant (P≥0.05 with student’s t-test), SD standard deviation, SJ swollen joint by clinical examination, TJ tender joint by clinical examination.
To dissect the effect of the overall perfusion of the hand from the perfusion due to active synovitis and to improve FOI results, novel FLRA scores were calculated for each individual joint as described above. The FLRO at the eponychium of the index finger ranged from 8.6 to 42.2 × 103 (mean 20.8 ± SD 9.5) for phase 1, 5.5 to 36.0 × 103 (mean 16.8 ± SD 7.7) for phase 2, and 3.1 to 25.3 × 103 (mean 10.7 ± SD 5.4) for phase 3. The derived values of the FLRAs ranged from 0.37 to 2.27 (mean 0.97 ± SD 0.39) for phase 1, 0.60 to 2.88 (mean 1.20 ± SD 0.39) for phase 2, and 0.62 to 2.87 (mean 1.23 ± SD 0.39) for phase 3. The results of the FLRAs are displayed in Table 3. Compared with the analysis of the FLRO, the FLRA results demonstrated improved discrimination between joints with compared with those without evidence of active synovitis resulting in significant differences of the calculated FLRA values compared with all clinical and imaging techniques in phases 2 and 3. Additionally, analyses comparing FOI with MRI stratified by joint type (carpal, MCP, PIP) were performed (data not shown). Due to the fact that 15 of 18 carpal joints displayed synovitis by MRI, no statistical significant differences were found for FLRO and FLRA for this subgroup analysis. The subgroup analyses of MCP and PIP joints revealed similar findings to the analysis of all joints, with better discrimination of FLRA than FLRO in both subgroups.
Table 3
Mean fluorescence ratios (standardized for overall perfusion of the hand) for joints with compared with those without evidence of synovitis determined by clinical examination or established imaging techniques #
  
Ratio FOI phase 1 (1 – 120 seconds)
Ratio FOI phase 2 (121 – 240 seconds)
Ratio FOI phase 3 (241 – 360 seconds)
Synovitis
n
Mean ± SD
P
Mean ± SD
P
Mean ± SD
P
TJ yes
44
1.02 ± 0.45
ns
1.31 ± 0.48
*
1.33 ± 0.48
*
TJ no
46
0.93 ± 0.33
1.10 ± 0.23
1.13 ± 0.24
SJ yes
26
1.13 ± 0.50
*
1.43 ± 0.54
**
1.45 ± 0.54
**
SJ no
64
0.91 ± 0.33
1.11 ± 0.26
1.14 ± 0.26
GSUS yes
39
1.06 ± 0.47
ns
1.33 ± 0.48
*
1.37 ± 0.48
**
GSUS no
51
0.91 ± 0.32
1.10 ± 0.26
1.12 ± 0.26
CDUS yes
23
1.22 ± 0.46
**
1.52 ± 0.52
**
1.53 ± 0.53
**
CDUS no
67
0.89 ± 0.33
1.09 ± 0.26
1.12 ± 0.26
MRI yes
39§
1.11 ± 0.46
**
1.38 ± 0.47
***
1.41 ± 0.46
***
MRI no
40§
0.86 ± 0.33
1.06 ± 0.26
1.08 ± 0.26
All
90
0.97 ± 0.39
 
1.20 ± 0.39
 
1.22 ± 0.39
 
# Fluorescence ratios were derived by dividing the readout of each joint by the readout of the control area of the eponychium of the index finger; § 11 joints could not be evaluated with MRI; *P<0.05; **P<0.01; ***P<0.001.
CDUS, color Doppler ultrasonography; FOI, fluorescence optical imaging; GSUS, grey-scale ultrasonography; MRI, magnetic resonance imaging; ns, comparison was not significant (P≥0.05 with student’s t-test); SD, standard deviation; SJ, swollen joint by clinical examination; TJ, tender joint by clinical examination.
A receiver-operating characteristic analysis, comparing the FLRAs of phase 1, phase 2, and phase 3 to detect synovitis confirmed by MRI as gold standard revealed the highest area under the curve for phase 3 (0.67), whereas lower values have been observed for phase 1 (0.58) and phase 2 (0.65). Using a cut-off value for the FLRA of phase 3 of more than 1.2 to detect MRI-confirmed synovitis with FOI, a sensitivity of 26 of 39 (67%; 95% confidence interval (CI), 51 to 79%) and a specificity of 31 of 40 (77%; 95% CI, 62 to 88%) were calculated, with a sensitivity of 21 of 32 (66%; 95% CI, 48 to 80%) for grade 1, and five of seven (71%; 95% CI, 36 to 92%) for grade 2 and 3 MRI-detected synovitis. A stratified analysis by joint type utilizing the same cut-off for FLRA of phase 3 to detect synovitis confirmed by MRI revealed a sensitivity/specificity of 87% (95% CI, 62 to 96%)/0% (95% CI, 0 to 56%) for carpal joints, 42% (95% CI, 23 to 62%)/93% (95% CI, 70 to 99%) for MCP joints, and 100% (95% CI, 57 to 100%)/77% (95% CI, 57 to 90%) for PIP joints.

Discussion

FOI with the Xiralite system is an emerging imaging technology. However, so far only semiquantitative analyses of FOI results have been reported limiting the strength and reliability of this method. Therefore, we aimed to establish a novel scoring system to allow for a quantitative FOI analysis: introducing and defining circular ROIs for five joints (wrist, MCP II and III, and PIP II and III) FLROs could be calculated representing the mean fluorescence intensity per pixel of the analyzed CI. In order to standardize the quantitative analysis for each patient individually, the FLRO at the eponychium of the index finger has been determined in each patient as a marker of the general perfusion. Dividing the readout of the joint ROI by the readout of the eponychium of the index finger, FLRAs could be calculated for each joint allowing quantitative analysis of FOI results in each patient individually. To validate the novel quantitative FOI scores, other imaging techniques (GSUS, CDUS, and MRI) as well as CE were applied to compare differentiation of joints with and joints without evidence of synovitis. To our knowledge this is the first study evaluating the ability of this novel imaging modality comparing quantitative fluorescence readout to synovitis detected by MRI and US.
In arthritic conditions, angiogenesis is highly dysregulated [33]. Furthermore, hypervascularisation and angiogenesis of the synovial membrane are a hallmark in RA patients [34] and strongly linked to bone destruction. The degree of synovial vascularisation correlates well with the disease activity of a given joint [35, 36], as well as radiographic progression [37] and with the therapeutic response in patients with RA [38]. Therefore, FOI might be a useful tool to detect and monitor disease activity in RA patients by visualization of microperfusion changes in affected joints.
Using the quantitative approach for the evaluation of the obtained FOI results, significant differences of the mean FLRO have been observed between synovitic and non-synovitic joints for the results of phases 2 and 3, which were even more striking after standardization by calculating the FLRAs. Unfortunately, no definite cut-off values for perfect separation of synovitic from non-synovitic joints could be established in our pilot study. However, a sensitivity of 67% and a specificity of 77% was calculated using a cut-off value for the FLRAs of phase 3 of more than 1.2 to detect MRI-confirmed synovitis with FOI, which demonstrates the diagnostic yield of this novel imaging method. The subgroup analyses stratified by joint type revealed for this cut-off a higher sensitivity for carpal and PIP joints than for MCP joints. Larger future studies should address if different joint types deserve distinct cut-offs for FLRA interpretation.
In each FOI sequence, three phases were scaled, giving different results in comparison to the other imaging modalities. In the publication by Werner et al. [8] phase 1 displayed the highest agreement with CE and CDUS, whereas the highest sensitivity was observed in phase 2, comparable with the sensitivity of US in relation to MRI. Using MRI as standard of reference, the FOI system displayed a sensitivity of 76% and a specificity of 54% using different analysis parameters. Consistent to these findings, a sensitivity of 67% and a specificity of 77% were calculated for FOI in our study compared with MRI findings. With regard to the different phases analyzed, our results differ partially to the previous observations, as phase 1 did not show similar significant results, whereas phases 2 and 3 correlated best with all imaging modalities following standardization.
In a recent study by Meier et al. [19], FOI was compared with CE and three T-weighted MRI. Using MRI as standard of reference, FOI displayed a sensitivity of 39.6% and a specificity of 85.2%. In that study, the diagnostic accuracy of the FOI was altogether lower and particularly limited in mild synovitis, whereas it performed substantially better in severely inflamed joints.
So far, different methods for interpreting the FOI results have been deployed [8, 19, 28]. Werner et al. [8] used a semiquantitative score, where the signal enhancement has been graded in percentages. In contrast, Meier et al. [19] utilized a semiquantitative assessment where synovitis was graded in each joint ranging from 0 to 3. As outlined by these investigators, a semiquantitative approach revealed only moderate interreader agreement with poor findings for the PIP and DIP joints, respectively [19]. Although we did not test for interreader agreement formally, our quantitative approach using directly computed FLRO and FLRA circumvents these problems of semiquantitative analyses.
In their study, Dziekan et al. used a ROI placed over the corresponding finger nail to standardize the FLRO of each finger joint to the interpersonal changes of overall perfusion [28]. Their quantitative analyses were not stratified into the three phases, as employed in our and other studies [8, 19, 28]. The authors noted that with their proposed method of quantitative FOI analysis a good separation between asymptomatic and inflamed joints (delineated by clinical examination of patients with RA) was not possible. They mainly attributed that finding to the lack of a ‘gold standard’ , because no other imaging methods (e.g. US or MRI) were employed in their study.
Werner et al. utilized the percentage of surface area of the affected joint to arrive at a ordinal scale from 0 to 3, whereas the publication by Meier et al. used the criteria of the RAMRIS semiquantitative scoring system [32], developed to evaluate synovitis detected by MRI, also for semiquantitative interpretation of the FOI data [8, 19]. Both approaches are based on changes of fluorescence intensity of the joint of interest compared with the fluorescence in unaffected joints over time, and are therefore not prone to be affected strongly by the background change of increasing and then decreasing concentrations of ICG. This difference of ICG concentrations during the three phases may explain why FLRA displayed a better discrimination between inflamed and non-inflamed joints then the plain FLRO results.
We are aware of some limitations concerning the image interpretation and quantification of pathological changes. Although the FOI procedure itself is standardized, consistent standards for image adjustment and automated interpretation are not yet established. We have chosen to set ROIs over those finger joints, which are typically involved in RA. This allows for better quantitative examination, but each ROI has to be set manually and the radius of the different ROIs needs still to be more accurately defined.

Conclusions

Our pilot study demonstrates that a quantitative assessment of the fluorescence results obtained by FOI is feasible, although so far no definite cut-off value could be delineated that perfectly separates inflamed from non-inflamed joints in patients with RA. Based on the better discrimination of FLRA compared with FLRO we postulate to use FLRA in larger studies to further set and evaluate the diagnostic yield of quantitative interpretation of FOI in the clinical care of patients with suspected or established RA.

Funding

The study was funded by internal research funds of the Department of Rheumatology and Clinical Immunology, Asklepios Medical Center Bad Abbach, Bad Abbach, Germany.

Competing interests

JB is employed by the manufacturer of the system and software used to perform FOI in this study. All other authors declare no conflict of interest.

Authors’ contributions

VS, WH, MF, and BE designed the study. VS and WH carried out the acquisition and quantification of clinical examination, sonography, and FOI data. PH graded the MRI examinations. JB contributed to the utilization of the FOI quantification software. VS and BE performed the statistical analysis. VS, WH, PH, CS, MM, MF, and BE analyzed and interpreted the data and prepared the manuscript. All authors read and approved the final manuscript.
Anhänge

Authors’ original submitted files for images

Below are the links to the authors’ original submitted files for images.
Literatur
1.
Zurück zum Zitat Scott DL, Coulton BL, Popert AJ: Long term progression of joint damage in rheumatoid arthritis. Ann Rheum Dis. 1986, 45: 373-378. 10.1136/ard.45.5.373.PubMedCentralCrossRefPubMed Scott DL, Coulton BL, Popert AJ: Long term progression of joint damage in rheumatoid arthritis. Ann Rheum Dis. 1986, 45: 373-378. 10.1136/ard.45.5.373.PubMedCentralCrossRefPubMed
2.
Zurück zum Zitat Scott DL, Smith C, Kingsley G: Joint damage and disability in rheumatoid arthritis: an updated systematic review. Clin Exp Rheumatol. 2003, 21: S20-S27.PubMed Scott DL, Smith C, Kingsley G: Joint damage and disability in rheumatoid arthritis: an updated systematic review. Clin Exp Rheumatol. 2003, 21: S20-S27.PubMed
3.
Zurück zum Zitat Gabriel SE: The epidemiology of rheumatoid arthritis. Rheum Dis Clin North Am. 2001, 27: 269-281. 10.1016/S0889-857X(05)70201-5.CrossRefPubMed Gabriel SE: The epidemiology of rheumatoid arthritis. Rheum Dis Clin North Am. 2001, 27: 269-281. 10.1016/S0889-857X(05)70201-5.CrossRefPubMed
5.
Zurück zum Zitat Wilke WS, Sweeney TJ, Calabrese LH: Early, aggressive therapy for rheumatoid arthritis: concerns, descriptions, and estimate of outcome. Semin Arthritis Rheum. 1993, 23: 26-41. 10.1016/S0049-0172(10)80005-8.CrossRefPubMed Wilke WS, Sweeney TJ, Calabrese LH: Early, aggressive therapy for rheumatoid arthritis: concerns, descriptions, and estimate of outcome. Semin Arthritis Rheum. 1993, 23: 26-41. 10.1016/S0049-0172(10)80005-8.CrossRefPubMed
6.
Zurück zum Zitat Quinn MA, Emery P: Window of opportunity in early rheumatoid arthritis: possibility of altering the disease process with early intervention. Clin Exp Rheumatol. 2003, 21: S154-S157.PubMed Quinn MA, Emery P: Window of opportunity in early rheumatoid arthritis: possibility of altering the disease process with early intervention. Clin Exp Rheumatol. 2003, 21: S154-S157.PubMed
7.
Zurück zum Zitat Kim JM, Weisman MH: When does rheumatoid arthritis begin and why do we need to know?. Arthritis Rheum. 2000, 43: 473-484. 10.1002/1529-0131(200003)43:3<473::AID-ANR1>3.0.CO;2-A.CrossRefPubMed Kim JM, Weisman MH: When does rheumatoid arthritis begin and why do we need to know?. Arthritis Rheum. 2000, 43: 473-484. 10.1002/1529-0131(200003)43:3<473::AID-ANR1>3.0.CO;2-A.CrossRefPubMed
8.
Zurück zum Zitat Werner SG, Langer HE, Ohrndorf S, Bahner M, Schott P, Schwenke C, Schirner M, Bastian H, Lind-Albrecht G, Kurtz B, Burmester GR, Backhaus M: Inflammation assessment in patients with arthritis using a novel in vivo fluorescence optical imaging technology. Ann Rheum Dis. 2012, 71: 504-510. 10.1136/annrheumdis-2010-148288.PubMedCentralCrossRefPubMed Werner SG, Langer HE, Ohrndorf S, Bahner M, Schott P, Schwenke C, Schirner M, Bastian H, Lind-Albrecht G, Kurtz B, Burmester GR, Backhaus M: Inflammation assessment in patients with arthritis using a novel in vivo fluorescence optical imaging technology. Ann Rheum Dis. 2012, 71: 504-510. 10.1136/annrheumdis-2010-148288.PubMedCentralCrossRefPubMed
9.
Zurück zum Zitat Backhaus M, Kamradt T, Sandrock D, Loreck D, Fritz J, Wolf KJ, Raber H, Hamm B, Burmester GR, Bollow M: Arthritis of the finger joints: a comprehensive approach comparing conventional radiography, scintigraphy, ultrasound, and contrast-enhanced magnetic resonance imaging. Arthritis Rheum. 1999, 42: 1232-1245. 10.1002/1529-0131(199906)42:6<1232::AID-ANR21>3.0.CO;2-3.CrossRefPubMed Backhaus M, Kamradt T, Sandrock D, Loreck D, Fritz J, Wolf KJ, Raber H, Hamm B, Burmester GR, Bollow M: Arthritis of the finger joints: a comprehensive approach comparing conventional radiography, scintigraphy, ultrasound, and contrast-enhanced magnetic resonance imaging. Arthritis Rheum. 1999, 42: 1232-1245. 10.1002/1529-0131(199906)42:6<1232::AID-ANR21>3.0.CO;2-3.CrossRefPubMed
10.
Zurück zum Zitat Szkudlarek M, Court-Payen M, Strandberg C, Klarlund M, Klausen T, Ostergaard M: Power Doppler ultrasonography for assessment of synovitis in the metacarpophalangeal joints of patients with rheumatoid arthritis: a comparison with dynamic magnetic resonance imaging. Arthritis Rheum. 2001, 44: 2018-2023. 10.1002/1529-0131(200109)44:9<2018::AID-ART350>3.0.CO;2-C.CrossRefPubMed Szkudlarek M, Court-Payen M, Strandberg C, Klarlund M, Klausen T, Ostergaard M: Power Doppler ultrasonography for assessment of synovitis in the metacarpophalangeal joints of patients with rheumatoid arthritis: a comparison with dynamic magnetic resonance imaging. Arthritis Rheum. 2001, 44: 2018-2023. 10.1002/1529-0131(200109)44:9<2018::AID-ART350>3.0.CO;2-C.CrossRefPubMed
11.
Zurück zum Zitat Backhaus M, Burmester GR, Sandrock D, Loreck D, Hess D, Scholz A, Blind S, Hamm B, Bollow M: Prospective two year follow up study comparing novel and conventional imaging procedures in patients with arthritic finger joints. Ann Rheum Dis. 2002, 61: 895-904. 10.1136/ard.61.10.895.PubMedCentralCrossRefPubMed Backhaus M, Burmester GR, Sandrock D, Loreck D, Hess D, Scholz A, Blind S, Hamm B, Bollow M: Prospective two year follow up study comparing novel and conventional imaging procedures in patients with arthritic finger joints. Ann Rheum Dis. 2002, 61: 895-904. 10.1136/ard.61.10.895.PubMedCentralCrossRefPubMed
12.
Zurück zum Zitat Klauser A, Frauscher F, Schirmer M, Halpern E, Pallwein L, Herold M, Helweg G, ZurNedden D: The value of contrast-enhanced color Doppler ultrasound in the detection of vascularization of finger joints in patients with rheumatoid arthritis. Arthritis Rheum. 2002, 46: 647-653. 10.1002/art.10136.CrossRefPubMed Klauser A, Frauscher F, Schirmer M, Halpern E, Pallwein L, Herold M, Helweg G, ZurNedden D: The value of contrast-enhanced color Doppler ultrasound in the detection of vascularization of finger joints in patients with rheumatoid arthritis. Arthritis Rheum. 2002, 46: 647-653. 10.1002/art.10136.CrossRefPubMed
13.
Zurück zum Zitat Brown AK: Using ultrasonography to facilitate best practice in diagnosis and management of RA. Nat Rev Rheumatol. 2009, 5: 698-706. 10.1038/nrrheum.2009.227.CrossRefPubMed Brown AK: Using ultrasonography to facilitate best practice in diagnosis and management of RA. Nat Rev Rheumatol. 2009, 5: 698-706. 10.1038/nrrheum.2009.227.CrossRefPubMed
14.
Zurück zum Zitat Szkudlarek M, Klarlund M, Narvestad E, Court-Payen M, Strandberg C, Jensen KE, Thomsen HS, Ostergaard M: Ultrasonography of the metacarpophalangeal and proximal interphalangeal joints in rheumatoid arthritis: a comparison with magnetic resonance imaging, conventional radiography and clinical examination. Arthritis Res Ther. 2006, 8: R52-10.1186/ar1904.PubMedCentralCrossRefPubMed Szkudlarek M, Klarlund M, Narvestad E, Court-Payen M, Strandberg C, Jensen KE, Thomsen HS, Ostergaard M: Ultrasonography of the metacarpophalangeal and proximal interphalangeal joints in rheumatoid arthritis: a comparison with magnetic resonance imaging, conventional radiography and clinical examination. Arthritis Res Ther. 2006, 8: R52-10.1186/ar1904.PubMedCentralCrossRefPubMed
15.
Zurück zum Zitat Terslev L, Torp-Pedersen S, Savnik A, von der Recke P, Qvistgaard E, Danneskiold-Samsoe B, Bliddal H: Doppler ultrasound and magnetic resonance imaging of synovial inflammation of the hand in rheumatoid arthritis: a comparative study. Arthritis Rheum. 2003, 48: 2434-2441. 10.1002/art.11245.CrossRefPubMed Terslev L, Torp-Pedersen S, Savnik A, von der Recke P, Qvistgaard E, Danneskiold-Samsoe B, Bliddal H: Doppler ultrasound and magnetic resonance imaging of synovial inflammation of the hand in rheumatoid arthritis: a comparative study. Arthritis Rheum. 2003, 48: 2434-2441. 10.1002/art.11245.CrossRefPubMed
16.
Zurück zum Zitat Boesen M, Ellegaard K, Boesen L, Cimmino MA, Jensen PS, Terslev L, Torp-Pedersen S, Danneskiold-Samsoe B, Bliddal H: Ultrasound doppler score correlates with OMERACT RAMRIS bone marrow oedema and Synovitis score in the wrist joint of patients with rheumatoid arthritis. Ultraschall Med. 2011, 33: 166-172. 10.1055/s-0029-1245922.CrossRef Boesen M, Ellegaard K, Boesen L, Cimmino MA, Jensen PS, Terslev L, Torp-Pedersen S, Danneskiold-Samsoe B, Bliddal H: Ultrasound doppler score correlates with OMERACT RAMRIS bone marrow oedema and Synovitis score in the wrist joint of patients with rheumatoid arthritis. Ultraschall Med. 2011, 33: 166-172. 10.1055/s-0029-1245922.CrossRef
17.
Zurück zum Zitat Chen WT, Mahmood U, Weissleder R, Tung CH: Arthritis imaging using a near-infrared fluorescence folate-targeted probe. Arthritis Res Ther. 2005, 7: R310-R317. 10.1186/ar1483.PubMedCentralCrossRefPubMed Chen WT, Mahmood U, Weissleder R, Tung CH: Arthritis imaging using a near-infrared fluorescence folate-targeted probe. Arthritis Res Ther. 2005, 7: R310-R317. 10.1186/ar1483.PubMedCentralCrossRefPubMed
18.
Zurück zum Zitat Wunder A, Tung CH, Muller-Ladner U, Weissleder R, Mahmood U: In vivo imaging of protease activity in arthritis: a novel approach for monitoring treatment response. Arthritis Rheum. 2004, 50: 2459-2465. 10.1002/art.20379.CrossRefPubMed Wunder A, Tung CH, Muller-Ladner U, Weissleder R, Mahmood U: In vivo imaging of protease activity in arthritis: a novel approach for monitoring treatment response. Arthritis Rheum. 2004, 50: 2459-2465. 10.1002/art.20379.CrossRefPubMed
19.
Zurück zum Zitat Meier R, Thürmel K, Moog P, Noël PB, Ahari C, Sievert M, Dorn F, Waldt S, Schaeffeler C, Golovko D, Haller B, Ganter C, Weckbach S, Woertler K, Rummeny EJ: Detection of synovitis in the hands of patients with rheumatological disorders: Diagnostic performance of optical imaging in comparison to MRI. Arthritis Rheum. 2012, 64: 2489-2498. 10.1002/art.34467.CrossRefPubMed Meier R, Thürmel K, Moog P, Noël PB, Ahari C, Sievert M, Dorn F, Waldt S, Schaeffeler C, Golovko D, Haller B, Ganter C, Weckbach S, Woertler K, Rummeny EJ: Detection of synovitis in the hands of patients with rheumatological disorders: Diagnostic performance of optical imaging in comparison to MRI. Arthritis Rheum. 2012, 64: 2489-2498. 10.1002/art.34467.CrossRefPubMed
20.
Zurück zum Zitat Fischer T, Gemeinhardt I, Wagner S, Stieglitz DV, Schnorr J, Hermann KG, Ebert B, Petzelt D, Macdonald R, Licha K, Schirner M, Krenn V, Kamradt T, Taupitz M: Assessment of unspecific near-infrared dyes in laser-induced fluorescence imaging of experimental arthritis. Acad Radiol. 2006, 13: 4-13. 10.1016/j.acra.2005.07.010.CrossRefPubMed Fischer T, Gemeinhardt I, Wagner S, Stieglitz DV, Schnorr J, Hermann KG, Ebert B, Petzelt D, Macdonald R, Licha K, Schirner M, Krenn V, Kamradt T, Taupitz M: Assessment of unspecific near-infrared dyes in laser-induced fluorescence imaging of experimental arthritis. Acad Radiol. 2006, 13: 4-13. 10.1016/j.acra.2005.07.010.CrossRefPubMed
21.
Zurück zum Zitat Fischer T, Ebert B, Voigt J, Macdonald R, Schneider U, Thomas A, Hamm B, Hermann KG: Detection of rheumatoid arthritis using non-specific contrast enhanced fluorescence imaging. Acad Radiol. 2010, 17: 375-381. 10.1016/j.acra.2009.09.016.CrossRefPubMed Fischer T, Ebert B, Voigt J, Macdonald R, Schneider U, Thomas A, Hamm B, Hermann KG: Detection of rheumatoid arthritis using non-specific contrast enhanced fluorescence imaging. Acad Radiol. 2010, 17: 375-381. 10.1016/j.acra.2009.09.016.CrossRefPubMed
22.
Zurück zum Zitat Hansch A, Frey O, Hilger I, Sauner D, Haas M, Schmidt D, Kurrat C, Gajda M, Malich A, Brauer R, Kaiser WA: Diagnosis of arthritis using near-infrared fluorochrome Cy5.5. Invest Radiol. 2004, 39: 626-632. 10.1097/01.rli.0000139008.04288.fd.CrossRefPubMed Hansch A, Frey O, Hilger I, Sauner D, Haas M, Schmidt D, Kurrat C, Gajda M, Malich A, Brauer R, Kaiser WA: Diagnosis of arthritis using near-infrared fluorochrome Cy5.5. Invest Radiol. 2004, 39: 626-632. 10.1097/01.rli.0000139008.04288.fd.CrossRefPubMed
23.
Zurück zum Zitat Hansch A, Frey O, Sauner D, Hilger I, Haas M, Malich A, Brauer R, Kaiser WA: In vivo imaging of experimental arthritis with near-infrared fluorescence. Arthritis Rheum. 2004, 50: 961-967. 10.1002/art.20112.CrossRefPubMed Hansch A, Frey O, Sauner D, Hilger I, Haas M, Malich A, Brauer R, Kaiser WA: In vivo imaging of experimental arthritis with near-infrared fluorescence. Arthritis Rheum. 2004, 50: 961-967. 10.1002/art.20112.CrossRefPubMed
24.
Zurück zum Zitat Simon GH, Daldrup-Link HE, Kau J, Metz S, Schlegel J, Piontek G, Saborowski O, Demos S, Duyster J, Pichler BJ: Optical imaging of experimental arthritis using allogeneic leukocytes labeled with a near-infrared fluorescent probe. Eur J Nucl Med Mol Imaging. 2006, 33: 998-1006. 10.1007/s00259-006-0081-y.CrossRefPubMed Simon GH, Daldrup-Link HE, Kau J, Metz S, Schlegel J, Piontek G, Saborowski O, Demos S, Duyster J, Pichler BJ: Optical imaging of experimental arthritis using allogeneic leukocytes labeled with a near-infrared fluorescent probe. Eur J Nucl Med Mol Imaging. 2006, 33: 998-1006. 10.1007/s00259-006-0081-y.CrossRefPubMed
26.
Zurück zum Zitat Meier R, Krug C, Golovko D, Boddington S, Piontek G, Rudelius M, Sutton EJ, Baur-Melnyk A, Jones EF, Daldrup-Link HE: Indocyanine green-enhanced imaging of antigen-induced arthritis with an integrated optical imaging/radiography system. Arthritis Rheum. 2010, 62: 2322-2327. 10.1002/art.27542.PubMedCentralCrossRefPubMed Meier R, Krug C, Golovko D, Boddington S, Piontek G, Rudelius M, Sutton EJ, Baur-Melnyk A, Jones EF, Daldrup-Link HE: Indocyanine green-enhanced imaging of antigen-induced arthritis with an integrated optical imaging/radiography system. Arthritis Rheum. 2010, 62: 2322-2327. 10.1002/art.27542.PubMedCentralCrossRefPubMed
27.
Zurück zum Zitat Scheel AK, Krause A, Rheinbaben IM, Metzger G, Rost H, Tresp V, Mayer P, Reuss-Borst M, Muller GA: Assessment of proximal finger joint inflammation in patients with rheumatoid arthritis, using a novel laser-based imaging technique. Arthritis Rheum. 2002, 46: 1177-1184. 10.1002/art.10226.CrossRefPubMed Scheel AK, Krause A, Rheinbaben IM, Metzger G, Rost H, Tresp V, Mayer P, Reuss-Borst M, Muller GA: Assessment of proximal finger joint inflammation in patients with rheumatoid arthritis, using a novel laser-based imaging technique. Arthritis Rheum. 2002, 46: 1177-1184. 10.1002/art.10226.CrossRefPubMed
28.
Zurück zum Zitat Dziekan T, Weissbach C, Voigt J, Ebert B, Macdonald R, Bahner ML, Mahler M, Schirner M, Berliner M, Berliner B, Osel J, Osel I: Detection of rheumatoid arthritis by evaluation of normalized variances of fluorescence time correlation functions. J Biomed Opt. 2011, 16: 076015-10.1117/1.3599958.CrossRefPubMed Dziekan T, Weissbach C, Voigt J, Ebert B, Macdonald R, Bahner ML, Mahler M, Schirner M, Berliner M, Berliner B, Osel J, Osel I: Detection of rheumatoid arthritis by evaluation of normalized variances of fluorescence time correlation functions. J Biomed Opt. 2011, 16: 076015-10.1117/1.3599958.CrossRefPubMed
29.
Zurück zum Zitat Schäfer VS, Hartung W, Ehrenstein B, Hoffstetter P, Müller M, Fleck M: A novel arthritis in vivo fluorescence optical imaging technology pushed to the limits. Rheumatology. 2013, 52: 1144-1145. 10.1093/rheumatology/kes301.CrossRefPubMed Schäfer VS, Hartung W, Ehrenstein B, Hoffstetter P, Müller M, Fleck M: A novel arthritis in vivo fluorescence optical imaging technology pushed to the limits. Rheumatology. 2013, 52: 1144-1145. 10.1093/rheumatology/kes301.CrossRefPubMed
30.
Zurück zum Zitat Prevoo ML, van’t Hof MA, Kuper HH, van Leeuwen MA, van de Putte LB, van Riel PL: Modified disease activity scores that include twenty-eight-joint counts. Development and validation in a prospective longitudinal study of patients with rheumatoid arthritis. Arthritis Rheum. 1995, 38: 44-48. 10.1002/art.1780380107.CrossRefPubMed Prevoo ML, van’t Hof MA, Kuper HH, van Leeuwen MA, van de Putte LB, van Riel PL: Modified disease activity scores that include twenty-eight-joint counts. Development and validation in a prospective longitudinal study of patients with rheumatoid arthritis. Arthritis Rheum. 1995, 38: 44-48. 10.1002/art.1780380107.CrossRefPubMed
31.
Zurück zum Zitat Backhaus M, Ohrndorf S, Kellner H, Strunk J, Backhaus TM, Hartung W, Sattler H, Albrecht K, Kaufmann J, Becker K, Sörensen H, Meier L, Burmester GR, Schmidt WA: Evaluation of a novel 7-joint ultrasound score in daily rheumatologic practice: a pilot project. Arthritis Rheum. 2009, 61: 1194-1201. 10.1002/art.24646.CrossRefPubMed Backhaus M, Ohrndorf S, Kellner H, Strunk J, Backhaus TM, Hartung W, Sattler H, Albrecht K, Kaufmann J, Becker K, Sörensen H, Meier L, Burmester GR, Schmidt WA: Evaluation of a novel 7-joint ultrasound score in daily rheumatologic practice: a pilot project. Arthritis Rheum. 2009, 61: 1194-1201. 10.1002/art.24646.CrossRefPubMed
32.
Zurück zum Zitat Østergaard M, Peterfy C, Conaghan P, McQueen F, Bird P, Ejbjerg B, Shnier R, O'Connor P, Klarlund M, Emery P, Genant H, Lassere M, Edmonds J: OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Core set of MRI acquisitions, joint pathology definitions, and the OMERACT RA-MRI scoring system. J Rheumatol. 2003, 30: 1385-1386.PubMed Østergaard M, Peterfy C, Conaghan P, McQueen F, Bird P, Ejbjerg B, Shnier R, O'Connor P, Klarlund M, Emery P, Genant H, Lassere M, Edmonds J: OMERACT Rheumatoid Arthritis Magnetic Resonance Imaging Studies. Core set of MRI acquisitions, joint pathology definitions, and the OMERACT RA-MRI scoring system. J Rheumatol. 2003, 30: 1385-1386.PubMed
33.
Zurück zum Zitat Kennedy A, Ng CT, Biniecka M, Saber T, Taylor C, O’Sullivan J, Veale DJ, Fearon U: Angiogenesis and blood vessel stability in inflammatory arthritis. Arthritis Rheum. 2010, 62: 711-721. 10.1002/art.27287.CrossRefPubMed Kennedy A, Ng CT, Biniecka M, Saber T, Taylor C, O’Sullivan J, Veale DJ, Fearon U: Angiogenesis and blood vessel stability in inflammatory arthritis. Arthritis Rheum. 2010, 62: 711-721. 10.1002/art.27287.CrossRefPubMed
34.
Zurück zum Zitat Pap T, Distler O: Linking angiogenesis to bone destruction in arthritis. Arthritis Rheum. 2005, 52: 1346-1348. 10.1002/art.21015.CrossRefPubMed Pap T, Distler O: Linking angiogenesis to bone destruction in arthritis. Arthritis Rheum. 2005, 52: 1346-1348. 10.1002/art.21015.CrossRefPubMed
35.
Zurück zum Zitat Lindblad S, Hedfors E: Intraarticular variation in synovitis. Local macroscopic and microscopic signs of inflammatory activity are significantly correlated. Arthritis Rheum. 1985, 28: 977-986. 10.1002/art.1780280904.CrossRefPubMed Lindblad S, Hedfors E: Intraarticular variation in synovitis. Local macroscopic and microscopic signs of inflammatory activity are significantly correlated. Arthritis Rheum. 1985, 28: 977-986. 10.1002/art.1780280904.CrossRefPubMed
36.
Zurück zum Zitat Ostergaard M, Hansen M, Stoltenberg M, Gideon P, Klarlund M, Jensen KE, Lorenzen I: Magnetic resonance imaging-determined synovial membrane volume as a marker of disease activity and a predictor of progressive joint destruction in the wrists of patients with rheumatoid arthritis. Arthritis Rheum. 1999, 42: 918-929. 10.1002/1529-0131(199905)42:5<918::AID-ANR10>3.0.CO;2-2.CrossRefPubMed Ostergaard M, Hansen M, Stoltenberg M, Gideon P, Klarlund M, Jensen KE, Lorenzen I: Magnetic resonance imaging-determined synovial membrane volume as a marker of disease activity and a predictor of progressive joint destruction in the wrists of patients with rheumatoid arthritis. Arthritis Rheum. 1999, 42: 918-929. 10.1002/1529-0131(199905)42:5<918::AID-ANR10>3.0.CO;2-2.CrossRefPubMed
37.
Zurück zum Zitat Fukae J, Kon Y, Henmi M, Sakamoto F, Narita A, Shimizu M, Tanimura K, Matsuhashi M, Kamishima T, Atsumi T, Koike T: Change of synovial vascularity in a single finger joint assessed by power doppler sonography correlated with radiographic change in rheumatoid arthritis: comparative study of a novel quantitative score with a semiquantitative score. Arthritis Care Res (Hoboken). 2010, 62: 657-663. 10.1002/acr.20110.CrossRef Fukae J, Kon Y, Henmi M, Sakamoto F, Narita A, Shimizu M, Tanimura K, Matsuhashi M, Kamishima T, Atsumi T, Koike T: Change of synovial vascularity in a single finger joint assessed by power doppler sonography correlated with radiographic change in rheumatoid arthritis: comparative study of a novel quantitative score with a semiquantitative score. Arthritis Care Res (Hoboken). 2010, 62: 657-663. 10.1002/acr.20110.CrossRef
38.
Zurück zum Zitat Taylor PC, Steuer A, Gruber J, Cosgrove DO, Blomley MJ, Marsters PA, Wagner CL, McClinton C, Maini RN: Comparison of ultrasonographic assessment of synovitis and joint vascularity with radiographic evaluation in a randomized, placebo-controlled study of infliximab therapy in early rheumatoid arthritis. Arthritis Rheum. 2004, 50: 1107-1116. 10.1002/art.20123.CrossRefPubMed Taylor PC, Steuer A, Gruber J, Cosgrove DO, Blomley MJ, Marsters PA, Wagner CL, McClinton C, Maini RN: Comparison of ultrasonographic assessment of synovitis and joint vascularity with radiographic evaluation in a randomized, placebo-controlled study of infliximab therapy in early rheumatoid arthritis. Arthritis Rheum. 2004, 50: 1107-1116. 10.1002/art.20123.CrossRefPubMed
Metadaten
Titel
Quantitative assessment of synovitis in patients with rheumatoid arthritis using fluorescence optical imaging
verfasst von
Valentin S Schäfer
Wolfgang Hartung
Patrick Hoffstetter
Jörn Berger
Christian Stroszczynski
Martina Müller
Martin Fleck
Boris Ehrenstein
Publikationsdatum
01.10.2013
Verlag
BioMed Central
Erschienen in
Arthritis Research & Therapy / Ausgabe 5/2013
Elektronische ISSN: 1478-6362
DOI
https://doi.org/10.1186/ar4304

Weitere Artikel der Ausgabe 5/2013

Arthritis Research & Therapy 5/2013 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Erhebliches Risiko für Kehlkopfkrebs bei mäßiger Dysplasie

29.05.2024 Larynxkarzinom Nachrichten

Fast ein Viertel der Personen mit mäßig dysplastischen Stimmlippenläsionen entwickelt einen Kehlkopftumor. Solche Personen benötigen daher eine besonders enge ärztliche Überwachung.

Nach Herzinfarkt mit Typ-1-Diabetes schlechtere Karten als mit Typ 2?

29.05.2024 Herzinfarkt Nachrichten

Bei Menschen mit Typ-2-Diabetes sind die Chancen, einen Myokardinfarkt zu überleben, in den letzten 15 Jahren deutlich gestiegen – nicht jedoch bei Betroffenen mit Typ 1.

15% bedauern gewählte Blasenkrebs-Therapie

29.05.2024 Urothelkarzinom Nachrichten

Ob Patienten und Patientinnen mit neu diagnostiziertem Blasenkrebs ein Jahr später Bedauern über die Therapieentscheidung empfinden, wird einer Studie aus England zufolge von der Radikalität und dem Erfolg des Eingriffs beeinflusst.

Costims – das nächste heiße Ding in der Krebstherapie?

28.05.2024 Onkologische Immuntherapie Nachrichten

„Kalte“ Tumoren werden heiß – CD28-kostimulatorische Antikörper sollen dies ermöglichen. Am besten könnten diese in Kombination mit BiTEs und Checkpointhemmern wirken. Erste klinische Studien laufen bereits.

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.