Skip to main content

16.05.2024 | Cataract

A Brillouin microscopy analysis of the crystalline lenses of Chinese adults with myopia

verfasst von: Yong Ma, Jian Cao, Yanze Yu, Teruko Fukuyama, Yongle Bao, Xuan Ding, Lingling Niu, Xingtao Zhou, Jing Zhao

Erschienen in: Graefe's Archive for Clinical and Experimental Ophthalmology

Einloggen, um Zugang zu erhalten

Abstract

To evaluate lenticular biomechanical and geometric parameters in Chinese adults with myopia and identify relevant factors using Brillouin microscopy (BM) and Pentacam. The biomechanical and geometric properties of the ocular lenses of Chinese adults with myopia were quantified using BM. Anterior segment images were acquired using a Pentacam. Correlated factors including age, sex, spherical equivalent (SE), intraocular pressure (IOP), axial length (AL), white-to-white ratio (WTW), central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA) were analyzed. We studied 65 eyes from 65 participants (mean age, 25.23 ± 6.12 years). Width of Top Plateau (WTP), Width of Bottom Plateau (WBP), Slope of Anterior Cortex (SAC), Slope of Posterior Cortex (SPC), and Height of Plateau (Height) metrics obtained using BM showed mean values of 2.597 ± 0.393 mm, 4.310 ± 0.535 mm, 1.344 ± 0.549 GPa/mm, –1.343 ± 0.480 GPa/mm, and 3.373 ± 0.048 GPa, respectively. No significant correlation was found between these parameters and sex, SE, IOP, CCT, ACA, or Height. Interestingly, WBP (r = 0.467, P < 0.001), SAC (r = 0.412, P = 0.001), and SPC (r = –0.280, P = 0.024) were significantly associated with age, and an age-related increase of WBP (slope of 35.36 ± 10.08 μm per year) was identified. Both ACD and ACV showed significant correlations with SAC (r = 0.329 and 0.380, P = 0.008 and 0.002, respectively), but not with SPC. BM provided a novel perspective on lenticular biomechanical and geometric properties in Chinese adults with myopia, which correlated with age, AL, WTW, ACD, and ACV.
Literatur
1.
Zurück zum Zitat Wang K, Pierscionek BK (2019) Biomechanics of the human lens and accommodative system: Functional relevance to physiological states. Prog Retin Eye Res 71:114–131CrossRefPubMed Wang K, Pierscionek BK (2019) Biomechanics of the human lens and accommodative system: Functional relevance to physiological states. Prog Retin Eye Res 71:114–131CrossRefPubMed
2.
Zurück zum Zitat Wei L, He W, Meng J, Qian D, Lu Y, Zhu X (2021) Evaluation of the White-to-White Distance in 39,986 Chinese Cataractous Eyes. Invest Ophthalmol Vis Sci 62(1):7CrossRefPubMedPubMedCentral Wei L, He W, Meng J, Qian D, Lu Y, Zhu X (2021) Evaluation of the White-to-White Distance in 39,986 Chinese Cataractous Eyes. Invest Ophthalmol Vis Sci 62(1):7CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Coleman DJ, Fish SK (2001) Presbyopia, accommodation, and the mature catenary. Ophthalmology 108(9):1544–1551CrossRefPubMed Coleman DJ, Fish SK (2001) Presbyopia, accommodation, and the mature catenary. Ophthalmology 108(9):1544–1551CrossRefPubMed
4.
Zurück zum Zitat Li Y, Zhu J, Chen JJ, Yu J, Jin Z, Miao Y, Browne AW, Zhou Q, Chen Z. Simultaneously imaging and quantifying in vivo mechanical properties of crystalline lens and cornea using optical coherence elastography with acoustic radiation force excitation. APL Photonics. 2019 Oct;4(10):106104 Li Y, Zhu J, Chen JJ, Yu J, Jin Z, Miao Y, Browne AW, Zhou Q, Chen Z. Simultaneously imaging and quantifying in vivo mechanical properties of crystalline lens and cornea using optical coherence elastography with acoustic radiation force excitation. APL Photonics. 2019 Oct;4(10):106104
5.
Zurück zum Zitat Cheng C, Parreno J, Nowak RB, Biswas SK, Wang K, Hoshino M, Uesugi K, Yagi N, Moncaster JA, Lo WK et al (2019) Age-related changes in eye lens biomechanics, morphology, refractive index and transparency. Aging 11(24):12497–12531CrossRefPubMedPubMedCentral Cheng C, Parreno J, Nowak RB, Biswas SK, Wang K, Hoshino M, Uesugi K, Yagi N, Moncaster JA, Lo WK et al (2019) Age-related changes in eye lens biomechanics, morphology, refractive index and transparency. Aging 11(24):12497–12531CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Hirasawa K, Nakakura S, Nakao Y, Fujino Y, Matsuura M, Murata H, Kiuchi Y, Asaoka R (2018) Changes in Corneal Biomechanics and Intraocular Pressure Following Cataract Surgery. Am J Ophthalmol 195:26–35CrossRefPubMed Hirasawa K, Nakakura S, Nakao Y, Fujino Y, Matsuura M, Murata H, Kiuchi Y, Asaoka R (2018) Changes in Corneal Biomechanics and Intraocular Pressure Following Cataract Surgery. Am J Ophthalmol 195:26–35CrossRefPubMed
8.
Zurück zum Zitat Weeber HA, Eckert G, Soergel F, Meyer CH, Pechhold W, van der Heijde RG (2005) Dynamic mechanical properties of human lenses. Exp Eye Res 80(3):425–434CrossRefPubMed Weeber HA, Eckert G, Soergel F, Meyer CH, Pechhold W, van der Heijde RG (2005) Dynamic mechanical properties of human lenses. Exp Eye Res 80(3):425–434CrossRefPubMed
9.
Zurück zum Zitat Besner S, Scarcelli G, Pineda R, Yun SH. In Vivo Brillouin Analysis of the Aging Crystalline Lens. Invest Ophthalmol Vis Sci. 2016 Oct 1;57(13):5093-5100 Besner S, Scarcelli G, Pineda R, Yun SH. In Vivo Brillouin Analysis of the Aging Crystalline Lens. Invest Ophthalmol Vis Sci. 2016 Oct 1;57(13):5093-5100
10.
Zurück zum Zitat Meng J, Wei L, He W, Qi J, Lu Y, Zhu X. Lens thickness and associated ocular biometric factors among cataract patients in Shanghai. Eye Vis (Lond). 2021 May 31;8(1):22 Meng J, Wei L, He W, Qi J, Lu Y, Zhu X. Lens thickness and associated ocular biometric factors among cataract patients in Shanghai. Eye Vis (Lond). 2021 May 31;8(1):22
11.
Zurück zum Zitat Henriquez MA, Mejías JA, Rincon M, Izquierdo L, Binder PS (2020) Correlation between lens thickness and lens density in patients with mild to moderate cataracts. Br J Ophthalmol 104(10):1350–1357CrossRefPubMed Henriquez MA, Mejías JA, Rincon M, Izquierdo L, Binder PS (2020) Correlation between lens thickness and lens density in patients with mild to moderate cataracts. Br J Ophthalmol 104(10):1350–1357CrossRefPubMed
12.
Zurück zum Zitat Ye Y, Zhao J, Niu L, Shi W, Wang X, Zhou X (2022) Long-term evaluation of anterior lens density after implantable collamer lens V4c implantation in patients with myopia over 40 years old. Br J Ophthalmol 106(11):1508–1513CrossRefPubMed Ye Y, Zhao J, Niu L, Shi W, Wang X, Zhou X (2022) Long-term evaluation of anterior lens density after implantable collamer lens V4c implantation in patients with myopia over 40 years old. Br J Ophthalmol 106(11):1508–1513CrossRefPubMed
13.
Zurück zum Zitat Vaughan JM, Randall JT (1980) Brillouin scattering, density and elastic properties of the lens and cornea of the eye. Nature 284(5755):489–491CrossRefPubMed Vaughan JM, Randall JT (1980) Brillouin scattering, density and elastic properties of the lens and cornea of the eye. Nature 284(5755):489–491CrossRefPubMed
14.
Zurück zum Zitat Ambekar YS, Singh M, Scarcelli G, Rueda EM, Hall BM, Poché RA, Larin KV. Characterization of retinal biomechanical properties using Brillouin microscopy. J Biomed Opt. 2020 Sep;25(9):090502 Ambekar YS, Singh M, Scarcelli G, Rueda EM, Hall BM, Poché RA, Larin KV. Characterization of retinal biomechanical properties using Brillouin microscopy. J Biomed Opt. 2020 Sep;25(9):090502
15.
Zurück zum Zitat Zhang H, Asroui L, Tarib I, Dupps WJ Jr, Scarcelli G, Randleman JB (2023) Motion-Tracking Brillouin Microscopy Evaluation of Normal, Keratoconic, and Post-Laser Vision Correction Corneas. Am J Ophthalmol 254:128–140CrossRefPubMed Zhang H, Asroui L, Tarib I, Dupps WJ Jr, Scarcelli G, Randleman JB (2023) Motion-Tracking Brillouin Microscopy Evaluation of Normal, Keratoconic, and Post-Laser Vision Correction Corneas. Am J Ophthalmol 254:128–140CrossRefPubMed
16.
Zurück zum Zitat Shao P, Seiler TG, Eltony AM, Ramier A, Kwok SJJ, Scarcelli G, Ii RP, Yun SH (2018) Effects of Corneal Hydration on Brillouin Microscopy In Vivo. Invest Ophthalmol Vis Sci 59(7):3020–3027CrossRefPubMedPubMedCentral Shao P, Seiler TG, Eltony AM, Ramier A, Kwok SJJ, Scarcelli G, Ii RP, Yun SH (2018) Effects of Corneal Hydration on Brillouin Microscopy In Vivo. Invest Ophthalmol Vis Sci 59(7):3020–3027CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Prevedel R, Diz-Muñoz A, Ruocco G, Antonacci G (2019) Brillouin microscopy: an emerging tool for mechanobiology. Nat Methods 16(10):969–977CrossRefPubMed Prevedel R, Diz-Muñoz A, Ruocco G, Antonacci G (2019) Brillouin microscopy: an emerging tool for mechanobiology. Nat Methods 16(10):969–977CrossRefPubMed
20.
Zurück zum Zitat Ambekar YS, Singh M, Zhang J, Nair A, Aglyamov SR, Scarcelli G, Larin KV. Multimodal quantitative optical elastography of the crystalline lens with optical coherence elastography and Brillouin microscopy. Biomed Opt Express. 2020 Mar 17;11(4):2041-2051 Ambekar YS, Singh M, Zhang J, Nair A, Aglyamov SR, Scarcelli G, Larin KV. Multimodal quantitative optical elastography of the crystalline lens with optical coherence elastography and Brillouin microscopy. Biomed Opt Express. 2020 Mar 17;11(4):2041-2051
21.
Zurück zum Zitat Scarcelli G, Kim P, Yun SH (2011) In vivo measurement of age-related stiffening in the crystalline lens by Brillouin optical microscopy. Biophys J 101(6):1539–1545CrossRefPubMedPubMedCentral Scarcelli G, Kim P, Yun SH (2011) In vivo measurement of age-related stiffening in the crystalline lens by Brillouin optical microscopy. Biophys J 101(6):1539–1545CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Rosales P, Dubbelman M, Marcos S, van der Heijde R (2006) Crystalline lens radii of curvature from Purkinje and Scheimpflug imaging. J Vis 6(10):1057–1067CrossRefPubMed Rosales P, Dubbelman M, Marcos S, van der Heijde R (2006) Crystalline lens radii of curvature from Purkinje and Scheimpflug imaging. J Vis 6(10):1057–1067CrossRefPubMed
24.
Zurück zum Zitat Xin X, Guo Q, Ming S, Liu C, Wang Z, Lei B (2021) High-Resolution Image Analysis Reveals a Decrease in Lens Thickness and Cone Density in a Cohort of Young Myopic Patients. Front Med 8:796778CrossRef Xin X, Guo Q, Ming S, Liu C, Wang Z, Lei B (2021) High-Resolution Image Analysis Reveals a Decrease in Lens Thickness and Cone Density in a Cohort of Young Myopic Patients. Front Med 8:796778CrossRef
25.
26.
Zurück zum Zitat Waring GOT, Chang DH, Rocha KM, Gouvea L, Penatti R (2021) Correlation of Intraoperative Optical Coherence Tomography of Crystalline Lens Diameter, Thickness, and Volume with Biometry and Age. Am J Pphthalmol 225:147–156CrossRef Waring GOT, Chang DH, Rocha KM, Gouvea L, Penatti R (2021) Correlation of Intraoperative Optical Coherence Tomography of Crystalline Lens Diameter, Thickness, and Volume with Biometry and Age. Am J Pphthalmol 225:147–156CrossRef
27.
Zurück zum Zitat Muralidharan G, Martínez-Enríquez E, Birkenfeld J, Velasco-Ocana M, Pérez-Merino P, Marcos S (2019) Morphological changes of human crystalline lens in myopia. Biomed Opt Express 10(12):6084–6095CrossRefPubMedPubMedCentral Muralidharan G, Martínez-Enríquez E, Birkenfeld J, Velasco-Ocana M, Pérez-Merino P, Marcos S (2019) Morphological changes of human crystalline lens in myopia. Biomed Opt Express 10(12):6084–6095CrossRefPubMedPubMedCentral
28.
Zurück zum Zitat Xie R, Zhou XT, Lu F, Chen M, Xue A, Chen S, Qu J (2009) Correlation between myopia and major biometric parameters of the eye: a retrospective clinical study. Optom Vision Sci : official Public Am Acad Optom 86(5):E503-508CrossRef Xie R, Zhou XT, Lu F, Chen M, Xue A, Chen S, Qu J (2009) Correlation between myopia and major biometric parameters of the eye: a retrospective clinical study. Optom Vision Sci : official Public Am Acad Optom 86(5):E503-508CrossRef
29.
Zurück zum Zitat Nangia V, Jonas JB, Sinha A, Matin A, Kulkarni M (2010) Central corneal thickness and its association with ocular and general parameters in Indians: the Central India Eye and Medical Study. Ophthalmology 117(4):705–710CrossRefPubMed Nangia V, Jonas JB, Sinha A, Matin A, Kulkarni M (2010) Central corneal thickness and its association with ocular and general parameters in Indians: the Central India Eye and Medical Study. Ophthalmology 117(4):705–710CrossRefPubMed
30.
Zurück zum Zitat Mohamed A, Nandyala S, Ho A, Manns F, Parel JA, Augusteyn RC (2021) Relationship of the cornea and globe dimensions to the changes in adult human crystalline lens diameter, thickness and power with age. Exp Eye Res 209:108653CrossRefPubMedPubMedCentral Mohamed A, Nandyala S, Ho A, Manns F, Parel JA, Augusteyn RC (2021) Relationship of the cornea and globe dimensions to the changes in adult human crystalline lens diameter, thickness and power with age. Exp Eye Res 209:108653CrossRefPubMedPubMedCentral
32.
Zurück zum Zitat Augusteyn RC (2018) On the contribution of the nucleus and cortex to human lens shape and size. Clin Exp Optom 101(1):64–68CrossRefPubMed Augusteyn RC (2018) On the contribution of the nucleus and cortex to human lens shape and size. Clin Exp Optom 101(1):64–68CrossRefPubMed
33.
Zurück zum Zitat Díez-Montero C (2023) López-de la Rosa A, López-Miguel A, Maldonado MJ: Relationship between the main components of the crystalline lens and the anterior chamber depth after cataract formation. Graefes Arch Clin Exp Ophthalmol 261(10):2853–2861CrossRefPubMedPubMedCentral Díez-Montero C (2023) López-de la Rosa A, López-Miguel A, Maldonado MJ: Relationship between the main components of the crystalline lens and the anterior chamber depth after cataract formation. Graefes Arch Clin Exp Ophthalmol 261(10):2853–2861CrossRefPubMedPubMedCentral
34.
Zurück zum Zitat Jonas JB, Nangia V, Gupta R, Sinha A, Bhate K (2012) Lens thickness and associated factors. Clin Exp Ophthalmol 40(6):583–590CrossRefPubMed Jonas JB, Nangia V, Gupta R, Sinha A, Bhate K (2012) Lens thickness and associated factors. Clin Exp Ophthalmol 40(6):583–590CrossRefPubMed
35.
Zurück zum Zitat Bolz M, Prinz A, Drexler W, Findl O (2007) Linear relationship of refractive and biometric lenticular changes during accommodation in emmetropic and myopic eyes. Br J Ophthalmol 91(3):360–365CrossRefPubMed Bolz M, Prinz A, Drexler W, Findl O (2007) Linear relationship of refractive and biometric lenticular changes during accommodation in emmetropic and myopic eyes. Br J Ophthalmol 91(3):360–365CrossRefPubMed
36.
Zurück zum Zitat Xiang Y, Fu T, Xu Q, Chen W, Chen Z, Guo J, Deng C, Manyande A, Wang P, Zhang H et al (2021) Quantitative analysis of internal components of the human crystalline lens during accommodation in adults. Sci Rep 11(1):6688CrossRefPubMedPubMedCentral Xiang Y, Fu T, Xu Q, Chen W, Chen Z, Guo J, Deng C, Manyande A, Wang P, Zhang H et al (2021) Quantitative analysis of internal components of the human crystalline lens during accommodation in adults. Sci Rep 11(1):6688CrossRefPubMedPubMedCentral
37.
Zurück zum Zitat Shammas HJ, Shammas MC (2015) Measuring the cataractous lens. J Cataract Refract Surg 41(9):1875–1879CrossRefPubMed Shammas HJ, Shammas MC (2015) Measuring the cataractous lens. J Cataract Refract Surg 41(9):1875–1879CrossRefPubMed
38.
Zurück zum Zitat Catania F, Morenghi E, Rosetta P, Paolo V, Vinciguerra R (2023) Corneal Biomechanics Assessment with Ultra High Speed Scheimpflug Camera in Primary Open Angle Glaucoma Compared with Healthy Subjects: A meta-analysis of the Literature. Curr Eye Res 48(2):161–171CrossRefPubMed Catania F, Morenghi E, Rosetta P, Paolo V, Vinciguerra R (2023) Corneal Biomechanics Assessment with Ultra High Speed Scheimpflug Camera in Primary Open Angle Glaucoma Compared with Healthy Subjects: A meta-analysis of the Literature. Curr Eye Res 48(2):161–171CrossRefPubMed
39.
Zurück zum Zitat Sun X, Dai Y, Chen Y, Yu DY, Cringle SJ, Chen J, Kong X, Wang X, Jiang C (2017) Primary angle closure glaucoma: What we know and what we don’t know. Prog Retin Eye Res 57:26–45CrossRefPubMed Sun X, Dai Y, Chen Y, Yu DY, Cringle SJ, Chen J, Kong X, Wang X, Jiang C (2017) Primary angle closure glaucoma: What we know and what we don’t know. Prog Retin Eye Res 57:26–45CrossRefPubMed
40.
Zurück zum Zitat Patel HY, Danesh-Meyer HV (2013) Incidence and management of cataract after glaucoma surgery. Curr Opin Ophthalmol 24(1):15–20CrossRefPubMed Patel HY, Danesh-Meyer HV (2013) Incidence and management of cataract after glaucoma surgery. Curr Opin Ophthalmol 24(1):15–20CrossRefPubMed
Metadaten
Titel
A Brillouin microscopy analysis of the crystalline lenses of Chinese adults with myopia
verfasst von
Yong Ma
Jian Cao
Yanze Yu
Teruko Fukuyama
Yongle Bao
Xuan Ding
Lingling Niu
Xingtao Zhou
Jing Zhao
Publikationsdatum
16.05.2024
Verlag
Springer Berlin Heidelberg
Erschienen in
Graefe's Archive for Clinical and Experimental Ophthalmology
Print ISSN: 0721-832X
Elektronische ISSN: 1435-702X
DOI
https://doi.org/10.1007/s00417-024-06510-0

Neu im Fachgebiet Augenheilkunde

Metastase in der periokulären Region

Metastasen Leitthema

Orbitale und periokuläre metastatische Tumoren galten früher als sehr selten. Aber mit der ständigen Aktualisierung von Medikamenten und Nachweismethoden für die Krebsbehandlung werden neue Chemotherapien und Strahlenbehandlungen eingesetzt. Die …

Staging und Systemtherapie bei okulären und periokulären Metastasen

Metastasen Leitthema

Metastasen bösartiger Erkrankungen sind die häufigsten Tumoren, die im Auge diagnostiziert werden. Sie treten bei ungefähr 5–10 % der Patienten mit soliden Tumoren im Verlauf der Erkrankung auf. Besonders häufig sind diese beim Mammakarzinom und …

CME: Wundheilung nach Trabekulektomie

Trabekulektomie CME-Artikel

Wird ein Glaukom chirurgisch behandelt, ist die anschließende Wundheilung von entscheidender Bedeutung. In diesem CME-Kurs lernen Sie, welche Pathomechanismen der Vernarbung zugrunde liegen, wie perioperativ therapiert und Operationsversagen frühzeitig erkannt werden kann.

„standard operating procedures“ (SOP) – Vorschlag zum therapeutischen Management bei periokulären sowie intraokulären Metastasen

Metastasen Leitthema

Peri- sowie intraokuläre Metastasen sind insgesamt gesehen selten und meist Zeichen einer fortgeschrittenen primären Tumorerkrankung. Die Therapie ist daher zumeist palliativ und selten kurativ. Zudem ist die Therapiefindung sehr individuell. Die …

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.